Magnets
Dipole Magnets:
| Quantity | Value |
| Number of Magnets | 12 |
| Nominal Field | 1.5 T |
| Maximum Field | 2.0 T |
| Bending Radius | 1.3354 m |
| Bending Angle | 30 deg |
| Gradient @ Nominal Field | - 2.8044 T/m |
| Hor. Good Field Region | +/- 2 cm |
| Ver. Good Field Region | +/- 2 cm |
| Field Quality (dB/B) | 0.05 % |
| Efficiency at Nominal Field | > 97 % |
| Efficiency at Maximum Field | > 73 % |
| Gap at beam trajectory (total) | 7.4 cm |
Quadrupole Magnets:
| Quantity | Value |
| Number of Magnets | 24 |
| Maximum Gradient | 15.6 T/m |
| Magnetic Length | 20 cm |
| Radius at the Pole Tip | 33 mm |
| Max Field @ Pole Tip | 0.50 T |
| Good Field Region Radius | 2 cm |
| Field Quality (dg/g) | 0.3 % |
Quadrupole-Octupole Magnets:
| Quantity | Value |
| Number of Magnets | 12 |
| Maximum Quad Gradient | 14.3 T/m |
| Magnetic Length | 20 cm |
| Radius at the Pole Tip | 33 mm |
| Good Field Region Radius | 2 cm |
| Field Quality (dg/g) | 0.3 % |
| Maximum (1/6 d3B/dx3) | 1250 T/m-3 |
| Total Field @ Pole Tip (max) | 0.46 + 0.04 = 0.5 T |
Quadrupole and Octupole windings must have independent
power supplies.
The ratio between quadrupolar and octupolar components
can change among different operation modes of the ring.
A solution with a completely independent octupolar magnet
separate from the quadrupole can be investigated as well.
In this case mechanical interferences with the other beamline
components must be carefully checked.
Sextupole Magnets:
| Quantity | Value |
| Number of Magnets | 30 |
| Maximum (1/2 d2B/dx2) | 390 T/m-2 |
| Magnetic Length | 15 cm |
| Radius at the Pole Tip | 33 mm |
| Max Field @ Pole Tip | 0.4 T |
| Good Field Region Radius | 2 cm |
| Field Quality (dg2/g2) | 0.5 % |
Correctors Magnets:
| Quantity | Value |
| Number of Hor. Magnets | 24 |
| Number of Vert. Magnets | 24 |
| Hor. Maximum Strength | 8 10-3 T m |
| Vert. Maximum Strength | 8 10-3 T m |
| Total Aperture | 66 mm |
The horizontal and vertical correctors can be assembled
together in a single hybrid element, in air or with a laminated iron body.
|